COM3C
COMITRONIC-BTI MALAYSIA SINGAPORE COMITRONIC SAFETY RELAY MALAYSIA SINGAPORE COMITRONIC SAFETY MODULES MALAYSIA SINGAPORE COM3C SAFETY RELAY MALAYSIA SINGAPORE COM3C - Two-hand control EN 574 and ISO 13849-1
COM3C - TWO-HAND CONTROL EN 574 AND ISO 13849-1
Two-hand control EN 574 and ISO 13849-1
Version for mechanical or touch buttons KOB101T
Controls the position of the press
Removable terminals
Two-hand control EN 574 and ISO 13849-1
Version for mechanical or touch buttons KOB101T
Controls the position of the press
Removable terminals
- Performance level with AWAX controller: PL = e
- Safety category: IIIC
- Safety Integrity Level: SIL 3
- Time before dangerous failure: MTTFd = 190 years
- Cycle before dangerous failure: B10d=100,000 at 5A
- Risk duration: 20 ms max.
- Cable severing protection: yes (opening of safety lines)
- Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant
- Indicators: 3 LEDs for diagnostics
- Reset: automatic with simultaneity control at 400 ms
- Position control: high press position contact input
- Mounting: symmetrical DIN 35mm rail on DIN 50022
- Mounting: IP 20 electrical box
- Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum
- Temperature: -20°C to +40°C
- Certification: INERIS 0080.5486.520.04.12.0059